Custom, Reliable Hydronic Systems
The Tamas Vitodens 100 boiler panel is specifically designed to accommodate the Viessmann, Vitodens 100 wall-mounted modular condensing boiler. This specialty panel is capable of handling BTU loads between 80,000 and 100,000. All panels include a control terminal, expansion tank and hose bib connections, as well as boiler connection unions.
The system can be configured with or without domestic hot water priority. A maximum of four zone pumps may be incorporated (three when domestic hot water priority is included). System flow rate and head is managed via the three speed zone pumps (Grundfos 15-58).
A zone pump may also be replaced by an injection mixing pump to distribute tempered water to the heating or cooling output device. Additional peripheral panels may be connected to the T-BO-VO-1110 to accommodate for larger applications requiring multiple zones or auxiliary devices or setpoints.
The Tamas Viessmann B1HA Series Boiler Panel product line contains a series of expandable panels suited for a variety of applications and building sizes using the Viessmann B1HA Boiler Series.
The Tamas Vitodens 200™ Boiler Panel is configured with expansion ports designed to accept input signals from future auxiliary boards. The panel is specifically designed to work in unison with the Viessmann Vitodens 200™ wall-mounted condensing boiler.
The Tamas Vitodens 100 Stainless steel boiler panel is pre-designed and assembled for a trouble free quick installation. The panel is designed to hook directly under a Vitodens 100 and work in perfect unison with the boiler.
For applications that require a high temperature zone that is not domestic hot water, a TMV is installed on the panel to allow for radiant floor "low temperature" zones. These panels string code start with T-BO-VO. The panel is also designed to hook directly under a Vitodens 100 and work in perfect unison with the boiler.
Height: 26in (662mm)
Width: 22in (560mm)
Depth: 12in (305mm)
Configuration Specific. See Resources.
Configuration Specific. See Resources.
95°C / 203°
3 Bar / 45 PSI
Galvanized Steel Backpan with Powder Coated Steel
Model Number | Viessmann Boiler Panels - Vitodens 100 Models (With DHW) |
T-BO-VD-1101 | Vitodens 100 Panel with (1) DHW Zone Priority and (1) Take Off |
T-BO-VD-1110 | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Low Temp Zone |
T-BO-VD-1111 | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Low Temp Zone |
T-BO-VD-1120 | Vitodens 100 Panel with (1) DHW Zone Priority, (2) Low Temp Zones and (1) Take Off |
T-BO-VD-1121 | Vitodens 100 Panel with (1) DHW Zone Priority, (2) Low Temp Zones and (1) Take Off |
T-BO-VD-1130 | Vitodens 100 Panel with (1) DHW Zone Priority, (3) Low Temp Zones |
T-BO-VD-1131 | Vitodens 100 Panel with (1) DHW Zone Priority, (3) Low Temp Zones and (1) Take Off |
T-BO-VD-1140 | Vitodens 100 Panel with (1) DHW Zone Priority and (4) Low Temp Zones |
T-BO-VD-1210 | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Hi Temp Zone and (1) Low Temp Zone |
T-BO-VD-1220 | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Hi Temp Zone and (2) Low Temp Zones |
T-BO-VD-1230 | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Hi Temp Zones and (3) Low Temp Zones |
T-BO-VD-1320 | Vitodens 100 Panel with (1) DHW Zone Priority, (2) Hi Temp Zones and (2) Low Temp Zones |
Model Number | Viessmann Boiler Panels - Vitodens 100 Models (No DHW) |
T-BO-VO-1011 | Vitodens 100 Panel with (1) Low Temp Zone and (1) Take Off |
T-BO-VO-1111 | Vitodens 100 Panel with (1) Hi Temp Zone and (1) Low Temp Zone and (1) Take Off |
T-BO-VO-1110 | Vitodens 100 Panel with (1) Hi Temp Zone and (1) Low Temp Zone |
T-BO-VO-1021 | Vitodens 100 Panel with (2) Low Temp Zones and (1) Take Off |
T-BO-VO-1031 | Vitodens 100 Panel with (3) Low Temp Zones and (1) Take Off |
T-BO-VO-1040 | Vitodens 100 Panel with (4) Low Temp Zones |
T-BO-VO-1050 | Vitodens 100 Panel with (5) Low Temp Zones |
T-BO-VO-1120 | Vitodens 100 Panel with (1) Hi Temp Zone and (2) Low Temp Zones |
T-BO-VO-1130 | Vitodens 100 Panel with (1) Hi Temp Zone and (2) Low Temp Zones |
T-BO-VO-1210 | Vitodens 100 Panel with (2) Hi Temp Zones and (1) Low Temp Zone |
T-BO-VO-1220 | Vitodens 100 Panel with (2) Hi Temp Zones and (2) Low Temp Zones |
Model Number | Viessmann 100-W B1HA Boiler Panels |
T-BO-VO-1101-N | Vitodens 100 B1HA Panel with (1) UPS 15-58 Zone pump, and (1) Take Off |
T-BO-VO-1100-N | Vitodens 100 B1HA Panel with (1) UPS 15-58 Zone pump |
T-BO-VO-1200-N | Vitodens 100 B1HA Panel with (2) UPS 15-58 Zone pumps |
T-BO-VO-1300-N | Vitodens 100 B1HA Panel with (3) UPS 15-58 Zone pumps |
T-BO-VO-1400-N | Vitodens 100 B1HA Panel with (4) UPS 15-58 Zone pumps |
T-BO-VO-1500-N | Vitodens 100 B1HA Panel with (5) UPS 15-58 Zone pumps |
T-BO-VO-1110-N | Vitodens 100 B1HA Panel with (1) UPS 15-58 High Temp Zone pump, (1) TMV, and (1) Low Temp Zone |
T-BO-VO-1210-N | Vitodens 100 B1HA Panel with (2) UPS 15-58 High Temp Zone pumps, (1) TMV, and (1) Low Temp Zone |
T-BO-VO-1220-N | Vitodens 100 B1HA Panel with (2) UPS 15-58 High Temp Zone pumps, (1) TMV, and (2) Low Temp Zones |
T-BO-VO-1230-N | Vitodens 100 B1HA Panel with (2) UPS 15-58 High Temp Zone pumps, (1) TMV, and (3) Low Temp Zones |
T-BO-VO-1320-N | Vitodens 100 B1HA Panel with (3) UPS 15-58 High Temp Zone pumps, (1) TMV, and (2) Low Temp Zones |
Model Number | Viessmann Boiler Panels - Vitodens 100 Models - Alpha Pumps (DHW) |
T-BO-VD-1110-A | Vitodens 100 Panel with (1) DHW Zone Priority, (1) Low Temp Zone and Alpha Pumps |
T-BO-VD-1120-A | Vitodens 100 Panel with (1) DHW Zone Priority, (2) Low Temp Zones and Alpha Pumps |
T-BO-VD-1130-A | Vitodens 100 Panel with (1) DHW Zone Priority, (3) Low Temp Zones and Alpha Pumps |
T-BO-VD-1140-A | Vitodens 100 Panel with (1) DHW Zone Priority, (4) Low Temp Zones and Alpha Pumps |
Model Number | Viessmann Boiler Panels - Vitodens 100 Models - Alpha Pumps (No DHW) |
T-BO-VO-1010-A | Vitodens 100 Panel with (1) Low Temp Zone and Alpha Pumps |
T-BO-VO-1020-A | Vitodens 100 Panel with (2) Low Temp Zones and Alpha Pumps |
T-BO-VO-1030-A | Vitodens 100 Panel with (3) Low Temp Zones and Alpha Pumps |
T-BO-VO-1040-A | Vitodens 100 Panel with (4) Low Temp Zones and Alpha Pumps |
Model Number | SS Viessmann Boiler Panels - Vitodens 100 Models (With DHW) |
T-BO-VD-1110-S | Stainless Steel Vitodens 100 Panel with (1) DHW Zone Priority, (1) Low Temp Zone |
T-BO-VD-1120-S | Stainless Steel Vitodens 100 Panel with (1) DHW Zone Priority, (2) Low Temp Zones |
T-BO-VD-1130-S | Stainless Steel Vitodens 100 Panel with (1) DHW Zone Priority, (3) Low Temp Zones |
Model Number | SS Viessmann Boiler Panels - Vitodens 100 Models (No DHW) |
T-BO-VO-1110-S | Stainless Steel Vitodens 100 Panel with (1) High Temp Zone, (1) Low Temp Zone |
T-BO-VO-1120-S | Stainless Steel Vitodens 100 Panel with (1) High Temp Zone, (2) Low Temp Zones |
Vitodens 100 Manual Vitodens 100-W B1HA Manual One Sheet Stainless Steel One Sheet